CFPP filterability

   
OELCHECK test instrument: PAC OptiFPP
Sample quantity: 45 ml
Unit: °C
Test result: CFPP
Analysis for:

fuels, heating oils particularly in case of problems in winter

Brief description: The sample is cooled down in a defined manner in a standardised vessel. The highest temperature at which the sample no longer flows through a standardised filtration device within a defined time is referred to as the cold filter plugging point (CFPP).
Statement:

This value is relevant to the low temperature suitability of diesel fuel and EL heating oil.

Underlying test standard: DIN EN 116, ASTM D6371