FE8-Test rig (oil)*

   
Test instrument: External laboratory
Sample quantity: 4 l
Unit: mg
Determined values: Wear values roller body and cage
Analysis for: Oils
Brief description: The FE8-test rig (oil) method according to DIN 51819-3 is used for the mechanical-dynamic testing of oils in rolling bearings in the area of mixed friction. 
Statement: The wear protection of oils is determined in the FE-8 test rig under realistic conditions with regard to bearing load and low rotational speeds on axial cylindrical roller bearings. 
In the wear test, the test duration and the weight loss of the bearing components are used to classify the lubricant suitability for the application.
Underlying test standard: DIN 51819-3